Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T03CM01795

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
05/29/2003 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*/ 1) WASTE AND VENT SYSTEM IS OK 2) OVERHEAD WATER DISTRIBUTION IS OK 30 OK FOR DRYWALL 4) GAS PRESSURE TEST IS OK
05/27/2003 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*/ 1) TRAP ARM FOR A.W. DOES NOT MEET MINIMUM TRAP ARM SIZE 2) CAN NOT HAVE A THREADED FITTING IN A CONSEALED LOCATION FOR SHOWER VENT 3) CAN NOT HAVE H. AND C. WATER TOUCHING EACH OTHER AND MUST BE STRAPED DOWN 4) CLOSET RING NOT INSTALLED 5) RE-TEST WATER AND VENT
05/22/2003 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*/ 1) NOT READY FOR INSPECTION