Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T03CM01511
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/28/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
09/22/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
09/15/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) A TRAP ARM MAY NOT CHANGE SIZE. TRAP AND TRAP ARM TO BE THE SAME SIZE. TAP MAY BE ONLY ONE SIZE LARGER THAN THE TAILPIECE TO WHICH IT IS CONNECTED. OK TO COVER ALL OTHER AREAS | |
08/27/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*/PA- 1)TEST ON WASTE VENTS & WATER -OK 2)TEST ON GAS OK 3)PLEASE SEE PLAN FOR LOCATION OF CO. SEE P-1 4)PLEASE INSTALL PER PLAN OR PROVIDE LETTER FROM ARCH. 5)PLEASE PROVIDE PLAN ON RO UNIT WITH SIZE OF LINE 6)SEE SEE SPEC FOR INSULATION-HOT SIDE & DON'T FORGET CONDINSATE. 7)RELIEF LINE MISSING & FLASHING NOT INSTALLED |