Date Description Inspector Results Comments
06/04/2004 GRADING - FINAL Approved
06/03/2004 GRADING - FINAL Denied THE BASIN EDGES ARE ACCEPTABLE AT THIS TIME. ADVISE ME ON THE LOOSE MATERIAL THAT IS LOCATED SOUTH OF THE BASIN. THIS MATERIAL NEEDS TO BE COMPACTED TO AN ACCEPTABLE LIMIT.
06/02/2004 GRADING - FINAL Denied SEE PREVIOUS COMMENTS. CONTACT DAVID ROBERTS AT 791-5550 EXT. 1194 AND ARRANGE FOR AN ON-SITE MEETING TO DISCUSS WHAT IS NEEDED TO COMPLETE THIS PERMIT.
05/25/2004 GRADING - FINAL Denied THE SOUTHERN BERM HAS NOT BEEN COMPLETED AS SHOWN ON THE APPROVED PLANS. THE DIMENSIONS THAT ARE SHOWN ON THE PLAN CALL FOR THE BERM TO BE APPROXIMATELY 12-FEET5 WIDE, THE FIELD MEASUREMENTS VARY FROM 5 TO 10-FEET. CHANGES OF THIS MAGNITUDE NEED TO BE APPROVED BY THE SIGNING ENGINEER FOR THE PROJECT.
05/07/2004 GRADING - FINAL Denied THE BASIN HAS NOT BEEN CONSTRUCTED PER THE APPROVED PLANS AS NOTED: 1) THE BERM ON THE NORTH SIDE OF THE BASIN IS SHOWN TO BE APPROXIMATELY 16 TO 18 FEET IN WIDTH, THE FIELD MEASUREMENTS SHOW TO BE APPROXIMATELY ONLY 5 FEET IN WIDTH. 2) THE SIDE SLOPES OF THE BASIN ARE CALLED OUT TO HAVE 4:1 SLOPES ON THE APPROVED PLANS. THE IN FIELD CONDITIONS ARE SHOWING TO BE 2:1 SLOPE RATIO'S OR LESS. 3) THE STABILITY OF THE SLOPES STILL ARE IN QUESTION AND WILL REQUIRE ADDITIONAL COMPACTION PRIOR TO THE RELEASE OF THIS SITE.
04/28/2004 GRADING - FINAL Denied CONTACT DAVID ROBERTS AT 349-5845 AND ARRANGE FOR AN ONSITE INSPECTION TO DISCUSS THE FOLLOWING PROBLEMS: THE RETENTION/DETENTION BASIN HAS NOT BEEN CONSTRUCTED PER THE APPROVED GRADING PLAN.