Inspection History Details
Inspection Status: Approved
Inspection History: GRADING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/11/2007 | GRADING - INTERMEDIATE | Approved | ||
| 07/19/2007 | GRADING - INTERMEDIATE | Correction Required | 1) PROVIDE TRUNCATED DOMES AT LANDINGS OF ALL HC RAMPS PER COT STD. DETAIL#207. 2) PROVIDE SECURITY BARRIERS AT THE TOP OF RET/DET BASIN SLOPES STEEPER THAN 4:1 WHERE WATER DEPTHS EXCEED 2'. PER DEV. STD 10-1.0 3) PROVIDE BOLLARDS AT THE SIDES OF THE TRASH ENCLOSURE, ENSURE ENCLOSURE INSIDE DIMENSIONS ARE 10X10' MIN. 4) PROVIDE GROUTED ROCK RIP RAP ON ALL SLOPES OF RET/DET BASIN AT 2:1 OR GREATER, PER YOUR APPROVED GRADING PLAN. 5) ANY SIGNIFICANT CHANGES MADE TO THE APPROVED GRADING PLAN MUST BE SUBMITTED AND APPROVED BY THE ENGINEER OF RECORD AND THE CITY OF TUCSON. |
|
| 04/23/2007 | GRADING - INTERMEDIATE | Not ready for Inspection | SPOKE WITH SUPERINTENDENT ABOUT SITE WORK FOR PROJECT |