Inspection Status: Violation
Inspection History: INITIAL CODE VIOLATION
| Date |
Description |
Inspector |
Results |
Comments |
| 12/04/2002 |
INITIAL CODE VIOLATION |
|
Violation |
VISITED SITE, WALKED UNIT WITH TENANTS SON, ED. MIN-HOUSING ISSUES FOUND ARE AS FOLLOWS (1) HAZARDOUS ELECTRICAL- OUTLETS CHECKED SHOWS REVERSED HOT NEUTREL IN KITCHEN, LIVINGROOM & BATHROOM, NON GROUNDED 3 PRONG OUTLETS IN LAUNDRY ROOM & S.E. BEDROOM, TOGGLE LIGHT SWITCH IN BATHROOM BURING FUSES WHEN ENERGIZED. EXTENTION CORD SUPPLYING POWER TO COOLER THUR DUCT WORK IN FURNANCE CLOSET. (2) LACKING SMOKE DETECTORS, EXISTING SMOKE DETECTOR IN KITCHEN NOT WORKING.OWNER WAS ORDERED TO REMOVE DETECTOR FROM KITCHEN & INSTALL NEW SMOKE DETECTORS WITHIN 24 HRS. (3) WEATHER PROTECTION-ENTRY DOOR, KITCHEN DOOR LACKING WEATHER STRIPPING & TRESHOLDS. S.W. BDRM-DETERIOURATED PLASTER BY WEST WINDOW,3" HOLE BEHIND DOOR CEILING TO WALL JOINT NEED TO BE SEALED. S.E. BDRM-1'X3' SECTION OF CEILING HAS COLLASPED DUE COOLER LEAK. WINDOWS THUR OUT UNIT WILL REQUIRE REGLAZING FOR WEATHERAZATION. VENT IN N.E. BDRM ALLOWING COLD TO ENTER UNIT AND MUST BE REMOVED & SEALED.(4) UNIT LACKING HEAT, FURNANCE NOT WORKING, ORDERED TO HAVE LICENCED CONTRACTOR SERVICE & START FURNANCE. CHECKED RECORDS PERMIT WAS ISSUED FOR INSTALLATION OF FURNANCE. (5) ADDITION OF EXTERIOUR WATER LINES WILL BE REFERRED TO D.S.D.(6) HAZARDOUS PLUMBING- HOT WATER TANK LEAKING FROM SPICKET, PLUMBING UNDER KITCHEN SINK LEAKING. MET WITH OWNER, WENT OVER ALL VIOLATION, ISSUED N OF O A.D.B. 24HRS. WAS GIVEN FOR SMOKE ALARMS, 5 DAYS FOR RESTOREATION OF HEAT, HAVE LICENCED CONTRACT CHECK ELECTRICAL & PULL ANY REQUIRED PERMITS. 30 DAYS WAS GIVEN FOR ALL OTHER REMAINING VIOLATION. 5 DAY FOLLOW UP. |