Case: T02VL02290
Case Details
Entered Date:
11/15/2002
Applicant:
SANCHEZ ELVIA M L
Description:
COMPLAINT:MIN HOUSING-PLUMBING LEAK UNDER SINK.
Outstanding Inspections
Case Number: T02VL02290
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/16/2003 | FOLLOW UP CODE VIOLATION | HLOPEZ | Violation | CONTACTED OWNER, MET ON SITE-SOME VIOLATIONS HAVE BEEN ADDRESSED. SMOKE ALARMS INSTALLED,REVERSED POLARITY OUTLET IN BATH RM.& KITCHEN CORRECTED, LIGHT SWITCH IN BATH RM. HAS BEEN REMOVED. VIOLATIONS NOT ABATED ARE (1) KITCHEN SINK PLUMBING LEAKING (2) VENT TO S.E. BED RM. TO EXTIOUR NOT SEALED (3) BOTH ENTRY DOORS LACKING WEATHER STRIPPING (4) HOT WATER TANK LEAKING AT HOSE BIB.(NOTE) OWNER HAD INSTALLED 3 SMOKE ALARMS.WHILE CHECKING ALARMS 2 WERE FOND NOT WORKING-TENANT STATED HE REMOVED BATTERYS FROM THEM REASON BEING THEY BURN ALOT OF INCENCE.INFORMED TENANT NOT TO REMOVE BATTERYS FROM ALARMS & KEEP INCENCE SMOKE AWAY FROM ALARMS. OWNER WILL INSTALL NEW BATTERYS TODAY. GAVE OWNER 14 DAYS TO ABATE REMAINING VIOLATIONS. |
| 12/04/2002 | INITIAL CODE VIOLATION | HLOPEZ | Violation | VISITED SITE, WALKED UNIT WITH TENANTS SON, ED. MIN-HOUSING ISSUES FOUND ARE AS FOLLOWS (1) HAZARDOUS ELECTRICAL- OUTLETS CHECKED SHOWS REVERSED HOT NEUTREL IN KITCHEN, LIVINGROOM & BATHROOM, NON GROUNDED 3 PRONG OUTLETS IN LAUNDRY ROOM & S.E. BEDROOM, TOGGLE LIGHT SWITCH IN BATHROOM BURING FUSES WHEN ENERGIZED. EXTENTION CORD SUPPLYING POWER TO COOLER THUR DUCT WORK IN FURNANCE CLOSET. (2) LACKING SMOKE DETECTORS, EXISTING SMOKE DETECTOR IN KITCHEN NOT WORKING.OWNER WAS ORDERED TO REMOVE DETECTOR FROM KITCHEN & INSTALL NEW SMOKE DETECTORS WITHIN 24 HRS. (3) WEATHER PROTECTION-ENTRY DOOR, KITCHEN DOOR LACKING WEATHER STRIPPING & TRESHOLDS. S.W. BDRM-DETERIOURATED PLASTER BY WEST WINDOW,3" HOLE BEHIND DOOR CEILING TO WALL JOINT NEED TO BE SEALED. S.E. BDRM-1'X3' SECTION OF CEILING HAS COLLASPED DUE COOLER LEAK. WINDOWS THUR OUT UNIT WILL REQUIRE REGLAZING FOR WEATHERAZATION. VENT IN N.E. BDRM ALLOWING COLD TO ENTER UNIT AND MUST BE REMOVED & SEALED.(4) UNIT LACKING HEAT, FURNANCE NOT WORKING, ORDERED TO HAVE LICENCED CONTRACTOR SERVICE & START FURNANCE. CHECKED RECORDS PERMIT WAS ISSUED FOR INSTALLATION OF FURNANCE. (5) ADDITION OF EXTERIOUR WATER LINES WILL BE REFERRED TO D.S.D.(6) HAZARDOUS PLUMBING- HOT WATER TANK LEAKING FROM SPICKET, PLUMBING UNDER KITCHEN SINK LEAKING. MET WITH OWNER, WENT OVER ALL VIOLATION, ISSUED N OF O A.D.B. 24HRS. WAS GIVEN FOR SMOKE ALARMS, 5 DAYS FOR RESTOREATION OF HEAT, HAVE LICENCED CONTRACT CHECK ELECTRICAL & PULL ANY REQUIRED PERMITS. 30 DAYS WAS GIVEN FOR ALL OTHER REMAINING VIOLATION. 5 DAY FOLLOW UP. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T02VL02290
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
| Date | Name |
| 03/14/2003 | CONTACTED IN PERSON |
| 12/06/2002 | NOTICE AND ORDER ISSUED |