Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/02/2004 |
PLUMBING - ROUGH, SOIL |
|
Approved |
|
| 11/07/2003 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) GREASE TRAP INSTALLED PER PLAN AS NOTED ON PLIL. 2) OK TO BACKFILL. |
| 07/01/2003 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) 60 POUNDS AIR PRESSURE TEST IS OK 2) THIS INSPECTION IS FOR YARD WATER SERVICE FOR BLDG #A, B, C, D AND E 3) NOTE: SEE DETAIL 213 ON P-1.2 ? BLOCKS |
| 06/30/2003 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) NOT READY FOR INSPECTION |
| 06/27/2003 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) SOIL WATER TEST IS OK 2) THIS INSPECTION IS FOR UG PLBG IN ROOMS 140, 141, 136, 137 AND NOTED ON PLAN 3) OK FOR BACKFILL |
| 06/23/2003 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) SOIL WATER TEST IS OK 2) THIS INSPECTION IS FOR ROOM #112, 108, 109 AND 105 AND BLDG SEWER AS NOTED ON PLAN 3) OK TO BACKFILL TRENCH |
| 06/20/2003 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 06/19/2003 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
IVRS - Inspection 0000* HAD MEETING WITH PLBG CONTRANCTOR ON PLAN ISSUES. |
| 06/18/2003 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) NOT READY FOR INSPECTION |
| 06/17/2003 |
PLUMBING - ROUGH, SOIL |
|
Denied |
1) 4 X 3 REDUCER FOR SOUTH BLDG. SEWER 2) NO TWO WAY CLEANOUT EACH BLDG. SEWER REQUIRES A TWO WAY CLEANOUT |
| 06/13/2003 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) CANNOT HAVE FLAT FACED BUSHING IN HORIZONTAL DRAINAGE SEE SEC. 311.5 94 UPC INTERPERTATION |
| 06/13/2003 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) SOIL WATER TEST IS OK 2) BLDG DRAIN IS STUBBED OUT OF BLDG ONLY 3) THIS INSPECTION IS BLDG C ONLY 4) OK FOR BACKFILL |