Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 02/24/2004 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 02/10/2004 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) CLOSET FLANGES HAVE BEEN POURED BUT REQUIRE INSIDE AND OUTSIDE CAULK OF JOINT. CALL BACK WHEN COMPLETE. 2) SOUTH EASTERN RAIN DRAIN IS LEAKING. CORRECTION MADE TO IN WALL OK. |
| 02/05/2004 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) WATER PIPING IN CONTACT WITH STEEL, NEEDS TEN MIL ALL LOCATIONS 2) WILL NEED TO SEE CLOSET FLANGES INSTALLED PRIOR TO TRIM 3) WATER SUPPLY TO SERVICE SINK TO BE 3/4" PER PLAN OR HAVE CITY APPROVED DRAWING SHOWING INSTALLATION |
| 10/28/2003 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*/ 2" TYPE K-H2O SERVICE STUBBED OUT OF PAD - 50 PSI TEST OK. CONTRACTOR TO WRAP ALL PIPING IN CONCRETE PRIOR TO POUR. |