Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02CM05550

Parcel: 134220030


Addresses:

6606 E LEHIGH DR

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
02/18/2004 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection 0000*
11/05/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000* UFER SHOULD BE IN BOTTOM 1/3 OF FOOTING. (2/0 ? 20' LONG CLAMPED TO CANT REBAR
10/28/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000* F1 FOOTING NOTES CALL FOR 4 EACH #4 CONT. DETAIL FOR FOOTING CALLS FOR 2 EACH #4 T, B AND 16" OC. SHOULD i ASSUME THAT NOTE FOR F1 MEANS 4 #4 (2EA T & B)? AND THAT THE 2 #4 16" OC IS ADDITIONAL FOR HIGHER STEMS?