Permit: T02CM04572

Parcel: 12714003F


Addresses:

373 N WILMOT RD


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T02CM04572

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
10/18/2002 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) OK TO DRYWALL.
10/14/2002 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.) MUST PROVIDE WATER TEST ON WASTE SYSTEM. 2.) CAN NOT HAVE FLAT FACED BUSHINGS ON HORIZONTAL DRAINAGE MUST USE BELL REDUCE SEE SECTION 311 94 UPC INTERPETATION. 3.) MUST HAVE 2" P-TRAPS ON 2" TRAP ARMS FOR TUB & SHOWER UNITS. 4.) MUST STRAP DOWN ALL HORIZONTAL WASTE EVERY 4'-0" WITH APPROVED STRAPS. P-TRAP IS NOT APPROVED MATERIAL.