Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/16/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 08/15/2002 |
FRAMING |
|
Denied |
1) BATHROOM EXHAUST FAN MUST BE EXHAUSTED OUTSIDE 2) BATHROOM ELECTRIC CIRCUIT MUST BE A 20 AMP ? WIRE CIRCUIT 3) ALL METAL ELECTRIC BOXES MUST BE PROPERLY GROUNDED NOT TO DRYWALL SCREWS 4) NO OTHER ROOM MAY BE ON BATHROOM ELECTRIC CIRCUIT 5) SMOKE DETECTORS CANNOT BE ON BATHROOM CIRCUIT 6) SHOWER P TRAP NOT INSTALLED 7) CANNOT APPROVE FRAME UNTIL ALL TRADES COMPLETE 8) SMOKE DETECTORS MUST BE LINKED TOGETHER |
| 08/12/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) NEED DWV TEST 2) NEED SHOWER P-TRAP 3) EAST WALL NOT FRAMED 4) ELECTRIC NOT DONE |