Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02CM03451

Parcel: 128010010

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T02CM03451

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/29/2002 PLUMBING - FINAL Approved CORRECTIONS MADE OK 2.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS.
10/28/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) A TRAP ARM MAY ONLY CHANGE DIRECTION 90 WITHOUT AN ADDITIONAL CLEAN OUT. 2.) CHANGES OF DIRECTION ON INDIRECT WASTE PIPING MAY REQUIRE ADDITIONAL CLEAN OUTS. 3.) PLUMBER TAPE IS NOT APPROVED STRAP.
10/28/2002 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*NOT READY FOR INSPECTION.