Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/09/2002 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 10/03/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) RE-INSPECTION 2) SAME REJECTION |
| 09/30/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999* COMPLETE INSTALLATION OF ALL FIXTURES. MOVE SMOKE ALARM AS INDICATED. UNCOVER ABS VENT & SINK, OUTSIDE |
| 09/26/2002 |
BUILDING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ NOTE: GAS PRESSURE TEST OK, YARD WATER OK, SEWER AND PLUMBING ARE OK TO COVER 1) FURNACE GAS VALVE AND CONNECTOR NOT IN. TUCSON BOX NOT SECURE. PAINT ABS 2) SMOKE DETECTORS REQUIRED 36" FROM AIR REGISTERS |
| 09/05/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) HCS NOT CONNECTED 2) PROVIDE 1" CLEARANCE AT WATER HEATER VENT FROM COMBUSTIBLES 3) NO PAPERWORK |
| 08/20/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0920*/ 1) SANITARY T FITTINGS NOT ALLOWED IN HORIZONTAL DRAINS EXPOSE ALL UNDERGROUND PLUMBING 2) BROKEN FITTING BY STREET 3) NO ACCESS. NEXT FAILURE WILL BE CHARGED A RE-INSPECTION FEE |
| 07/19/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) WATER CLOSET NOT VENTED THRU ROOF UNABLE TO FIND VENT TERMINATION 2) INADEQUATE VENT SIZE PER UPC 904 12.5 SQUARE FOOT INCHES REQUIRED 3) ABS PLUMBING NOT ALLOWED ON EXTERIOR OF BUILDING BELOW ROOF 4) PROVIDE CITY OF TUCSON APPROVED SEWER/PLUMBING PLAN 5) PROVIDE PROOF OF INSPECTION OF SEWER DRAIN WASTE AND VENT SYSTEM, OR EXPOSE ALL PLUMBING FOR INSPECTION 6) PROVIDE SEWER TEST PER UPC SECTION 712.2 7) DUCT WORK MUST BE INSULATED WITH MINIMUM R-6 AND INSTALLED PER CODE 8) PROVIDE MINIMUM 10 PSI GAS PRESSURE TEST PER UPC (204.3) 9) OUTSIDE ELECTRIC OUTLETS MUST BE GFCI PROTECTED 10) WATER HEATER REQUIRED 5 FT VENT AND ENCLOSURE 11) BACK WATER VALVE REQUIRED ON SEWER 12) KITCHEN COUNTER REQUIRES GFCI OUTLETS ON EACH COUTNER WITHIN 2 FT 13) ALL BEDROOMS REQUIRE AT LEAST BATTERY OPERATED SMOKE DETECTORS 14) LABEL ALL CIRCUITS IN ELECTRIC PANEL 15) IF YOU DESIRE TEMP POWER THEN REMOVE ALL CIRCUIT BREAKERS-INSTALL ONE 20 AMP C/B W MAINTENANCE GFCI OUTLET. THEN REQUEST TEMPORARY POWER INSPECTION 16) BOND GAS LINE 17) PULL W/C FOR INSPECTION 18) COOLER REQUIRES TUCSON BOX |