Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/08/2003 | PLUMBING - SEWER HCS CONNECT | Approved | IVRS - Inspection 0000*1.) 2 1/2" SCH 40 PVC YARDWATER INSTALLATION OK PENDING ARCHETECT APPROVAL OK TO COVER. 2.) SEWER CROSSING STREET OK DIP EITHER SIDE WATER MAIN 6' OK TO COVER. |
|
| 01/03/2003 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection 0000*NOT READY FOR INSPECTION. | |
| 01/02/2003 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection 0000* | |
| 12/30/2002 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection 0000* | |
| 12/30/2002 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection 0999*1.) WATER MAIN REQUIRES TWO FEET CLEAR BETWEEN SEWER AND WATER PIPING OR INSTALL DIP 6 FEE EITHER SIDE OF WATER MAIN. 2.) HCS TIE IN AT MAIN OK SADDLE TAP OK. 3.) OK TO COVER TO MIDDLE OF STREET. 4.) OK TO COVER FROM DIRECTIONAL CLEANOUT TO CURB. |