Inspection History: PLUMBING - FINAL

Permit Number - T02CM02632

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/12/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*CORRECTIONS MADE OK PLUMBING FINAL OK
2.) OK FOR C OF O PENDING ANY OTHER INSPECTION.
03/10/2003 PLUMBING - FINAL Denied ALL ROOF PENETRATIONS REQUIRE PROPERLY SIZED FLASHING I NEED ACCESS TO ALL AREAS LEAD FLASHING OBSTRUCTS CROSS SECTIONAL AREA OF VENT.2.) WATER CLOSETS REQUIRE 15" FROM CENTERLINE TO SIDEWALL OR OBSTRUCTION.
3.) URINAL (HC) REQUIRES 15" FROM SIDEWALL TO CENTER.
4.) WHAT PROTECTS THE POTABLE WATER FROM BACKFLOW/SIPHORAGE WITHIN THE PARK.
03/04/2003 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*NOT READY FOR INSPECTION.
12/04/2002 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*1.) FITTINGS NOT INSTALLED PER MANUFACTURER'S INSTALLATION RECOMMENDATIONS.
2.) POINT OF VENT MAY NOT BE BELOW THE WEIR OF THE TRAP.