Inspection History Details
Inspection Status: Approved
Inspection History: STEM WALL/RETAINING WALL
Permit Number - T02CM02265
Inspection Description - STEM WALL/RETAINING WALL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/06/2002 | STEM WALL/RETAINING WALL | Approved | IVRS - Inspection 0000* | |
| 11/04/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*A-3-4 | |
| 10/28/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*NE LOADING DOCK. | |
| 09/25/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*RAMP WALL OK TO POUR. | |
| 09/23/2002 | STEM WALL/RETAINING WALL | Denied | IVRS - Inspection 0999*1.) SEE GSN'S ON 51. YOU NEED 1 1/2" CLEAR FROM FACE OF WALL TO REBAR. 2.) SEE 05/52 FOR LENGTH OF DEVELOPED LAP SPLICES FOR #5 REBAR IN STEM WALL. 3.) SEE 105/56. YOUR VERTICALS DO NOT EXTEND FULL HEIGHT OF RAMP WALL 2" YOU ARE MISSING THE #4 HORIZONTAL @ TOP OF WALL. | |
| 09/20/2002 | STEM WALL/RETAINING WALL | Not ready for Inspection | IVRS - Inspection 0000* | |
| 09/13/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*OK TO COVER WELD PLATES LINE 11 & N & W WALLS 2.) I NEED TO SEE EPOXY REPORTS FOR EMBEDS AND RFI FOR NEW PLATES ON PANEL 27. 3.) I AM NOT ACCEPTING REPORT FROM WTI DATED 9-13 I KNOW THAT S WALL WAS GROUTED BEFORE THIS INSPECTION CARD. | |
| 09/11/2002 | STEM WALL/RETAINING WALL | Not ready for Inspection | IVRS - Inspection 0000* | |
| 08/23/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*TILT PANELS 7,12,17,22 13,15,16,23 1.) PLEASE WATCH VIBRATION OF CONCRETE & MAKE SURE ALL OF PAD IS DONE. PLEASE BRING BOTTOM OF PANEL 6 WHERE HONEY COMBED TO ENGINEERS ATTN. | |
| 08/22/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* | |
| 08/20/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*TILT PANELS 6,9,11,21, OK TO POUR WHEN APPROVED BY WESTERN TECH. | |
| 08/19/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*PARTIAL TILT PANELS 5,8,14,&24. | |
| 08/16/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*1,2,3,4,10,25,26,27, | |
| 08/15/2002 | STEM WALL/RETAINING WALL | Denied | IVRS - Inspection 0999*IMPROPER SPACING BETWEEN ADJ BARS. | |
| 08/13/2002 | STEM WALL/RETAINING WALL | Cancelled | IVRS - Ri canceled |