Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/13/2003 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 01/02/2003 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) A/C CONDENSOR DISCONNECTS NOT PERMITTED TO BE BEHIND UNITS MINIMUM WORK SPACE REQUIRED IS 36D X 30W 2) CLEANOUT NORTH SIDE NEAR ELECTRIC PANEL REQUIRES PROPER CAP OR PLUG 3) WIRING FOR HOOD MUST TERMINATE IN APPROVED DEVICE OR BOX |
| 12/23/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) FURNACE ELECTRIC NOT CONNECTED 2) 2ND FLOOR BATH ELECTRIC INCOMPLETE 3) ELECTRIC IN 2ND FLOOR WATER HEATER/FURNACE CLOSET MUST BE FIXTURED OR CAPPED 4) ELECTRIC INCOMPLETE, INSPECTION STOPPED |