Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/25/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 09/23/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) MAKE UP ALL GROUND WIRES IN BOXES 2) NO OUTLET ALLOWED UDNER COUNTER OVERHANG OF 6" OR MORE 3) LAUNDRY TRAP ARM WEIR MUST BE BETWEEN 6 AND 18" ABOVE FLOOR 4) PEX MUST BE 12" FROM RECESSED LIGHTS 5) BEARING WALL OVER BOARDED FOR PLUMBING 6) REVISE PLAN FOR ADDED LAUNDRY AND ELECTRIC RANGE CIRCUIT ON 2ND FLOOR |
| 09/19/2002 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |