Permit: T02CM01019

Parcel: 12620001A


Addresses:

1100 S ALVERNON WY


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T02CM01019

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
05/05/2003 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection 0000*PERIMETER WALL & SHOT CUTE.
04/28/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*N BOX .
04/23/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
04/17/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
04/08/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
04/01/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
03/31/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*STAIRS
03/20/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*S. ELEC. RM RAMP.
03/05/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
02/25/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*N WASH. VEH. MAINT.
02/12/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
02/10/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
02/06/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*RAMP
02/04/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
01/31/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*GRID 1 TO 1
01/27/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
01/24/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
01/23/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*grid #1 & south
01/16/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*GRID 8 BCD
01/14/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
01/13/2003 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection 0000*
01/10/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*9 to 12.5 Grid.
01/09/2003 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection 0000*
01/08/2003 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection 0000*
01/07/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*GRID 3-1
01/06/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
1.) PARTIAL FILL FOOTERS AND F1 FOOTER GRID A/5-8.5. NEED #5 VERTS AT JAMB A 4.75 AND A8.75
2.) PROVIDE AFI FOR OFFSET OF VERTICALS TO BLOCK WALL @ B-25/6. (FOUNDATION VERTS 12" TOO FAR EAT).
01/03/2003 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection 0000*
12/31/2002 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*/ 1) COMPLETE VOULT FOOTINGS AREA B6 2) RETAIN FOOTING FOR RAMP AT D.7/S.5-9 INCLUDING RAMP FOOT LINE 7 ALSO LINE S.5/D-E EXCLUDING CORNER AT DS.5
12/30/2002 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*1.D.S/9 F2 FOOT SOUTH
2.) 3.75-6/D.S.-E
3.) FB FOOTING B2 B3 B4.
12/26/2002 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*1. FB FOOTINGS @/4,5,7,8,9
2.) F20 FOOTINGS @ B/5.5 & 6.5.
3.) F10 FOOTINGS @ DS & D4.
12/24/2002 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection 0000*
12/23/2002 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection 0000*CANCELLED BY CONTRACTOR.
12/20/2002 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*1.) GRIDLINE D/2,3,6,7,8,9 ISOLATED FOOTINGS #3 RINGS INSTALLED ON A.BOLTS OK TO POUR.
12/19/2002 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*1.) ISOLATED FOOTING @ D 2,3,6,7,8,9.
2.) 12PM INSPECTION #3 RINGS FOR COL BOLTS NOT INSTALLED HOLD POUR TILL APPROVED.
12/18/2002 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
12/17/2002 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*GRID 2.5-7 EAST BLD WALL F3 FOOTING EXTENDED. TO GRID 6' PER ENGINEER. I NEED SPECIAL INSP REPORT FROM 12-9 FOR EAST WALL FOOTINGS GRID 7-15.5.
12/09/2002 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*OK H BAR @ WALL EXTENSION.
12/05/2002 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*1.) HEADWALL EXTENSIONS ON CALVERT SEE DETAILS 12 ON C3.2 AND ADOT B-250. 1.) H-H BARS FOR HEADWALLS NOT EXTENDED PER ADOT B-02.50. PLEASE PROVIDE RFI FOR REPAIR OF THIS OVERSIGHT.
11/26/2002 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*1.) OK TO POUR CULVERT TOP WHEN CONFORMANCE OBSERVED BY SPECIAL INSPECTOR
2.) FINISH BLOWING OUT DEBRIS CHECK 1" CLEARANCE FROM BOTTOM, KNOCK DOWN HIGH TIE WIRES & COMPLETE INSTALLATION OF BURB. VERTS.
11/15/2002 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
11/13/2002 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
11/08/2002 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
BASE OF BOX CALVERT OK TO POUR.