Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - CABLE DROP
Permit Number - T01EL02657
Inspection Description - ELECTRIC - CABLE DROP
Inspection Status - Denied
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/01/2001 | ELECTRIC - CABLE DROP | Denied | SERVICE 1. BOARD BEHIND SERVICE TO BE PAINTED 2.) NEED WATER & GAS BOND 3.) RISER TO HAVE 2 SUPPORTS BELOW ROOF USE NEW SUPPORT ALSO INSTALL A GUY BACK SUPPORT SINCE RISER 3 ABOVE ROOF. 4.) ADDRESS SERVICE. HOUSE HAS HAD REWIRING DONE TO ALL INSIDE CHECKED WITH OFFICE, THERE IS NO RECORD OF PERMIT OR INSPECTION. YOU WILL HAVE TO OBTAIN A PERMIT FOR WIRING INSIDE AND PROVIDE A PLAN TO DEVELOPMENT SERVICE GET APPROVED AND RECALL INSPECTION. HAVE YOUR ELECTRICIAN DRAW UP PLAN AND SUBMIT. |