Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date |
Description |
Inspector |
Results |
Comments |
| 06/18/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Approved |
IVRS - Inspection 0000* |
| 04/15/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 02/14/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*TOW MAIN BUILDING I NEED TO SEE DRYPACK UNDER STEEL POSTS BEFORE YOU COVER. DO NOT SPLICE REBAR WITHIN 8' OF CONTROL JOINT. |
| 02/13/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*PARTIAL 16' MAIN; 4' COLUMNS. |
| 02/11/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*PARTIAL 16' |
| 02/08/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*12' |
| 02/07/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*PARTIAL 12' |
| 02/06/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*3L OK |
| 02/05/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*PARTIAL KEEP GROUT DOWN 2" - 4" FROM TOP OF 2ND LIFT. |
| 02/01/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*IL EXCEPT NEED 30% INCREASE ON LAP SPLICE WHERE TWO BARS ARE IN SAME CELL. |
| 01/31/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Not ready for Inspection |
IVRS - Inspection 0000*NOT READY. |