Inspection Status: Partial Approval
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T01CM04733
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/07/2002 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1.) CORRECTIONS MADE OK 2.) NEED TO SEE CLOSET FLANGES 3.) NEED TO SEE THE REST OF THE EXPOSED PIPING IN THE BASEMENT. 4.) OK TO COVER WALLS. 5.) OK FOR CEILING TILE. | |
01/04/2002 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*1.) SUPPORT HORIZONTAL N/H PIPE WITHIN 18" OF CHANGE OF DIRECTION OR COUPLING. 2.) TAIL PIECE MAY NOT EXCEED 24" 3.) WATER TEST TO 10' MINIMUM 4.) OK FOR SHEETROCK ONE SIDE ONLY. | |
01/02/2002 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000* | |
12/21/2001 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000*1.)NOT TO CODE. 2.) NOT INSTALLED AS PER APPROVED PLANS 3.) PLEASE INSTALL AS PER PLAN ON PROVIDE APPROVED REVISED PLAN BOB CALL JIM 349-5029 |