Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T01CM03877
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/04/2002 | BUILDING - FINAL | Approved | ||
03/01/2002 | BUILDING - FINAL | Partial Approval | IVRS - Inspection 0000*OK TEMP C OF O. OK FOR TEMP C OF O. EVERYTHING APPROVED EXCEPT FINAL INSTALLATION OF CEILING GRID. AS PREVIOUSLY NOTED THE GRID IS LACKING THE PERIMETER WIRES REQUIRED BY SECTION 25-2 OF THE BUILDING CODE (ASTM REB 636-639). FURTER MORE THE GRID HAS NOT BEEN INSTALLED PER THE RECCOMENDATIONS OF CISCA. CISCA INSTALLATION NOTE #6 FOR ZOND 2 REQUIRES SPACER BARS AT WALL CLOSURES AND DOES NOT PERMIT THE USE OF POP-RIVETS. THE CITY OF TUCSON BUILDING DEPT. IS REVIEWING THE APPLICATION FO THE CISCA STANDARD BUT WE DO NOT ALLOW TAKING THE LEAST RESTRICTURE PARTIONS OF 2 DIFFERENT METHODS. | |
02/26/2002 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*1.) PROVIDE ELECTRIC & MECHANICAL FINAL. 2.) CEILING GRID TO BE INSTALLED PER BUILDING CODE PERIMETER WIRES ON ALL MAIN & CROSS RUNNERS WITHIN 8" OF AL PERIMETER OF GRID. | |
02/21/2002 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*1.) I NEED APPROVED PLUMBING, LECTRIC AND MECHANICAL INSPECTION FORMS. 2.) I DO NOT RECALL DOING ANY ABOVE CEILING INSPECTION PLEASE PROVIDE ORIGINAL INSPECTION CARD AND/OR AN APPROVED INSPECTION REPORT FOR CEILING GRID INSTALLATION. |