Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 03/04/2002 |
BUILDING - FINAL |
|
Approved |
|
| 03/01/2002 |
BUILDING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*OK TEMP C OF O. OK FOR TEMP C OF O. EVERYTHING APPROVED EXCEPT FINAL INSTALLATION OF CEILING GRID. AS PREVIOUSLY NOTED THE GRID IS LACKING THE PERIMETER WIRES REQUIRED BY SECTION 25-2 OF THE BUILDING CODE (ASTM REB 636-639). FURTER MORE THE GRID HAS NOT BEEN INSTALLED PER THE RECCOMENDATIONS OF CISCA. CISCA INSTALLATION NOTE #6 FOR ZOND 2 REQUIRES SPACER BARS AT WALL CLOSURES AND DOES NOT PERMIT THE USE OF POP-RIVETS. THE CITY OF TUCSON BUILDING DEPT. IS REVIEWING THE APPLICATION FO THE CISCA STANDARD BUT WE DO NOT ALLOW TAKING THE LEAST RESTRICTURE PARTIONS OF 2 DIFFERENT METHODS. |
| 02/26/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) PROVIDE ELECTRIC & MECHANICAL FINAL. 2.) CEILING GRID TO BE INSTALLED PER BUILDING CODE PERIMETER WIRES ON ALL MAIN & CROSS RUNNERS WITHIN 8" OF AL PERIMETER OF GRID. |
| 02/21/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) I NEED APPROVED PLUMBING, LECTRIC AND MECHANICAL INSPECTION FORMS. 2.) I DO NOT RECALL DOING ANY ABOVE CEILING INSPECTION PLEASE PROVIDE ORIGINAL INSPECTION CARD AND/OR AN APPROVED INSPECTION REPORT FOR CEILING GRID INSTALLATION. |