Permit: T01CM02163

Parcel: 137335720


Addresses:

1800 W VALENCIA RD

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
06/20/2001 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*1)BARKERY/DELI UNDERGROUND OK.WATER TEST OK.2)TRANSITION
FITTINGS OK.3)COMBO WASTE ANDF VENT INSTALLED CORRECTLY.4)OK TO BACKFILL.
06/19/2001 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*DELI/BAKERY COMBO WASTE AND VENT.1)CONNECTION BETWEEN N/H AND ABS TO BE MADE WITH MISSION COUPLING-ALSO FLOOR SINKS MADE ON THE HORIZONTAL.3)COMBO WASTE AND VENT SYSTEM VENT TO BE TIED IN DOWNSTREAM FROM LAST TRAP.