Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/24/2002 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000*CORRECTIONS REQUESTED HAVE BEEN COMPLETE THANK YOU. |
| 07/17/2002 |
ELECTRIC - FINAL |
|
Partial Approval |
IVRS - Inspection 0000* WASTE WATER MOTOR & EQUIPMENT & WIRING IS OK. |
| 07/11/2002 |
ELECTRIC - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 07/01/2002 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0245*ON GOING 2035 INTERMEDIATE ELECTRIC AND 02090 ELECTRIC FINAL, PER EACH AREA NOTED. 1.) ROOF A/C UNITS OK THREE DISCONNECTS TO BE INSTALLED ON SMALL CONDENSORS. 2.) AMMOWIA COOLING/CONDENSIDIG TOWER OK 3.) PROCESS/CAN LINE SOME DISCONNECTS TO MOTOR HAVE GROUNDING WIRE MISSING. 4.) 340-5 T.C. CABLE 318-6 BONDING & 300-8 ARE NE CODE SECTIONS WHICH APPLY TO TRAY CABLE ( TYPE TC AND MOTOR CONNECTIONS AT STORK MACHINE BASEMENT AND OTHER LOCATIONS. SEE SUMMARY 7-2-02 GUARD SHACK LOAD CENTER NORTH ENTRANCE COMPLETED 2.) WASTEWATER PARTIAL INTERMEDIATE. 3.) BOILER ROOM COMPLETED 4.) COMPRESSOR ROOM AIR & CHILLERS. COMPLETED. WED 6-26-02. 1.) PROCESS MEZZANINE INSPECT ELECTRICAL PIPING & HARDWARE 2.) MEZZANINE #4 INSPECT ELECTRICAL PIPING & HARDWARE. 3.) AND PANEL DOOR FASTENING. LABELING OF EQUIPMENT IS ON GOING. 4.) REVIEW MCC'S 3 AND 4 COMPLETED. 1.) DRY POWDER RM. MOTOR DISCONNECTS NOT LABELED NOT A DDE AREA. 2.) PROCESS AREA. SOME MOTOR DISCONNECTS ARE NOT LABELED. MOTORS NOT BOLTED TO SUPPORTING FRAME NOT A CODE REQUIREMENT JUST AN ALERT. LIQUIFIER ROOM 1.) 480 V 3 FEEDER FROM J-BOX TO MONORAIL ART 430-13 CRANE TRAC SHOULD HAVE PLASTIC BUSHING OR SHORT NM FLEX CONDUIT SLEEVE FOR PROTECT CONDUCTORS.M S B 5 LABELS TO PANELS & OTHER GEAR MISSING. |
| 06/28/2002 |
ELECTRIC - FINAL |
|
Partial Approval |
IVRS - Inspection 0000* |
| 06/27/2002 |
ELECTRIC - FINAL |
|
Partial Approval |
IVRS - Inspection 0000* |
| 06/26/2002 |
ELECTRIC - FINAL |
|
Partial Approval |
IVRS - Inspection 0000* |
| 06/25/2002 |
ELECTRIC - FINAL |
|
Partial Approval |
IVRS - Inspection 0000* |
| 05/30/2002 |
ELECTRIC - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 02/05/2002 |
ELECTRIC - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000* |