Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T01CM02145
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/24/2002 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection 0000* | |
07/01/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000* | |
06/28/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000* | |
06/27/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000* | |
06/26/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000* | |
06/25/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000* | |
05/09/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000* | |
04/08/2002 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000* | |
04/08/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000* | |
03/25/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1.) SHIPPING & RCV'D 2.) LIGHTING CONTROLS FOR AREA 13. 3.) WASTEWATER GROUNDING. | |
03/19/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1.) OK TO ENERGIZE PNL. EBIF. 2.) OK TO MCC1A & MCC2A. | |
03/18/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000* 1.) UFER @ CENTRAL PLANT OK TO GAS & COLD WTR. | |
03/15/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1. KRAK COMPUTER A/C. 2. FIRE PMP TRANSFORMER. | |
03/13/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000* A.) DISCONNECT 1-3-4 ALCOVE DISCONNECTS TO KRK UNIT, FOR COMPUTER RM 2.) PNL SBIB OK TO ENERGIZE. THANKS | |
03/12/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000* 1.) OFFICE LOBBY LITING J BOXES PULLED IN. | |
03/04/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | VRS - Inspection 0000*HI BAY LITING PROCESS AREA. | |
02/27/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1.) EMERGENCY POWER PANEL FOR GENERATOR POWER. OK TO ENERGIZE. 2.) CIELING LIGHT OUTLETS & CONDUIT AREA 4 FRONT PORCH. | |
02/22/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1.) EAST QUARTER OF OFFICE SECTION INCLUDED BATHROOM EAST. | |
02/21/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1.) PANEL RP1A-OK TO ENERGIZE. 2 T FMR #T5B TO RP 5B PNL. CORRECTION REQUIRED 1.) DISCONNECT #WP2. MUST BE MOVED TO ALLOW FOR 36" CLEARANCE IN FRONT OF SWITCH. | |
02/13/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1.) ENERGIZING OF PPA TO LP1A. | |
02/08/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1.) SEE NOTE BELOW PARTIAL 2.) LOAD CENTERS CENTRAL PLANT ARE OK CLOSE AS NEEDED.3.) MSB3 ENERGIZING SUBPNL. LP.3A BEFORE CLOSING UP ANY LOAD CENTER BE SURE ALL DEBRIS AND DUST DIRT HAVE BEEN REMOVED. GIVE FINAL TORQUE ADJUSTMENT TO TERMINAL LUGS AND CHECK FOR PROPER PHASE TAPING. THANKS. | |
02/06/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*LINE FEEDERS TO CHILLERS, BOILERS, AND COOLING TOWER PUMPS. 2.) ROUGH IN OF WALLS AND ABOVE CIELING IN LAB, OFFICE AND PROCESS CONTROL AREA. CENTRAL OFFICE CORRIDOR. | |
02/05/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000* | |
01/31/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1.) MSB 1 MSB POWER WIRING & GRD. OK 2.) MSB4 4.MSB3. S TEST RESULT MANUAL RECEIVED ALL HI-VOLTAGE & MSB TFMR. TEST & GFI MBRKR TESTS. | |
01/29/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1.) WALL ROUGH IN OK AREA 4. 2.) CIELING J-BOXES ONLY. | |
01/24/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*OK TO CLEAR SERVICE ENTRANCE SECTION JOHN FURLEIGH ELECTRICAL CONTRACTORS REP. TO KEEP SES COMPARTMENTS LOCKED OUT WITH EXCEPTION TO AUTHORIZED PERSONAL. LOCKED OUT WITH EXCEPTION TO AUTHORIZED PERSONAL. |