Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM01139

Parcel: 136253230


Addresses:

3360 S IRENE PL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/11/2001 FRAMING Approved IVRS - Inspection 0000*
04/26/2001 FRAMING Partial Approval IVRS - Inspection 0000*/1) AC WIRE WEST WALL DAMAGED BY LATH STAPLES 2) BLOCK AT SHEAR PANEL REMOVED GARAGE WALL, TOP PLATES OF PANELS NOT NAILED TO ROOF DECK