Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T01CM00807
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/13/2001 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000* OK TO COVER | |
04/04/2001 | PLUMBING - INTERMEDIATE | Not ready for Inspection | NOT READY | |
03/19/2001 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*1) NEED TO SEE CONNECTIONS UNDER SLAB (PLBG ROUGH/SOIL) BLDG DRAIN MAY BE UNDER SIZED ONLY 3 WATER CLOSETS ALLOWED ON 3" DRAIN. 2) SEE 905.3 VENT GRADES AND CONNECTIONS. 3) SEE 905.3 VERTICAL WET VENTING. 4) PROVIDE REVISED AND APPROVED PLBG PLAN. 5) WATER TEST TO 42" |