Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T01CM00806
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/18/2001 | ELECTRIC - FINAL | Approved | ||
07/11/2001 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection 0000*2 SEISMIC TIES REQUIRED FOR EACH FIXTURE ONE SCREW THROUGH "T" BAR TO EACH FIXTURE AT ENDS SUPPORT M.C. CABLE WITHIN 12" OF BOX AND AT EVERY 6 FT. NEED DISCONNECT SWITCH FOR WATER HEATER OR OTHER EFFECTIVE MEANS. NEED TO HAVE METAL EMBOSSED TAPE OR ENGRAVED METAL TAGS FOR SERVICE ADDRESS AND DISCONNECT NUMBERS. |