Permit: T01CM00803

Parcel: 137090090


Addresses:

5452 S 12TH AV #100


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T01CM00803

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/17/2001 PLUMBING - FINAL Approved
07/06/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) HC WATER CLOSETS REQUIRE THE FLUSH HANDLE TO BE ON THE LARGE OPENING SIDE. 2.) HC LAVATORIES REQUIRE INSULATION KITS. 3.) WATER CLOSETS NEED TO BE CAULKED TO THE FLOOR 4.)HOSE BIBBS REQUIRE VACUUM BREAKERS 5.) PROVIDE CERTIFICATION OF RPBP 6.) WATER HEATER NEEDS A DRAIN PAN AND DRAIN. 7.) T & P DRAIN TO RUN TO OUTSIDE AND TERMINATE 6" AFF.