Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T01CM00803
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/17/2001 | PLUMBING - FINAL | Approved | ||
07/06/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) HC WATER CLOSETS REQUIRE THE FLUSH HANDLE TO BE ON THE LARGE OPENING SIDE. 2.) HC LAVATORIES REQUIRE INSULATION KITS. 3.) WATER CLOSETS NEED TO BE CAULKED TO THE FLOOR 4.)HOSE BIBBS REQUIRE VACUUM BREAKERS 5.) PROVIDE CERTIFICATION OF RPBP 6.) WATER HEATER NEEDS A DRAIN PAN AND DRAIN. 7.) T & P DRAIN TO RUN TO OUTSIDE AND TERMINATE 6" AFF. |