Permit: T01BU01411

Parcel: 137335720


Addresses:

1840 W VALENCIA RD

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
11/01/2001 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection 0000*
10/30/2001 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection 0000*RESCHEDULED BY CONTRACTOR.
10/26/2001 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection 0999*1.) PROVIDE LIC # FOR CONTRACTOR DOING THIS WORK. 2.) PLEASE VERTICAL REBAR PER APPROVED PLAN 3.) PROVIDE GRADE STAKES & REMOVE WOOD DROM FORM EXCAVATION 4.) REINFORCE CONCRETE TO BE INSTALLED PER AC1 318 & 540.
10/24/2001 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection 0999*1.3" OF CLEARANCE REQUIRED BETWEEN ALL REBAR AND EARTH 2.) PLEASE CLEAN OUT LOOSE DIRT IN FORM 3.) YOUR VERTICAL ARE SUPPOSED TO BE FOR A 24" WIDE MONUMENT; YOU HAVE THEM PLACED 36" APART. PLEASE MOVE TO PROPER LOCATION (8" EACH SIDE OF CENTERLINE.
08/02/2001 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection 0000*
07/31/2001 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection 0000*