Inspection Status: Denied
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/02/2001 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection 0999*1.) NO MESSAGE LEFT ON IVR, CALLED MR JOSE ESTRELLA 971-9060 NO ANSWER 2.) DUE TO ALL THE ELECTRICAL PROBLEM ON THIS JOB THE OCCUPANT HAS BEEN REQUIRED TO OBTAIN A C-11 LICENSED ELECTRIAL CONTRACTOR PRIOR TO ANY INSPECTIONS THIS HAS NOT BEEN DONE INSPECTION TO BE HELD UNTIL CONTRACTOR VERIFIED. | |
| 08/02/2001 | ELECTRIC - RECONNECT | Denied | NEED PERMIT NEED PLAN AND APPROVED FOR INTERIOR WIRING NEED MIN HOUSING APPROVAL TO REFER TO RAY MAJUTA. | |
| 02/13/2001 | ELECTRIC - RECONNECT | Denied | YOU WILL NEED TO GET A C-11 LICENCE TO CHECK ALL ELECTRICAL WORK- WE WILL NEED VERIFICATION FROM ELECTRICIAN TO OUR OFFICE. | |
| 11/22/2000 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection 0999* 1. RISER TO BE 2" RIGID AT 3' ABOVE ROOF WIRE IN RISE TO BE #4 COPPER AND PROVIDE 2' OUT OF WEATHER HEAD NEED A GROUND SYSTEM FOR SERVICE-2 GROUND RODS AND GROUND TO WATERLINE USE CORRECT TYPE CIRCUIT BREAKERS AND SIZES SEAL ALL HOLES ON SERVICE NEED A BUSHING WHERE ALL WIRES COME THUR BOX NEED 2 SUPPORTS ON RISER THERE IS TO MUCH OPEN WIRING THRU OUT HOUSE TO RELEASE POWER GENERATOR NOT TO BE CONNECTED TO HOUSE WIRING ONLY TO SEPERATE CORD SUGGEST YOU OBTAIN ELECTRICAL CONTRACTOR TO CORRECT WIRING. CALLED OWNER JOSE ESTRELLA TO SAY AFTER INSPECTION FOR RECONNECT AT 1608 S FREMONT, T00EL02722 AFTER COMING INTO OFFICE TO CHECK PREVIOUS RECORDS AT THIS ADDRESS. THERE HAS NEVER BEEN ANY TYPE OF PERMIT OBTAINED FOR NEW WIRING FOR MOST OF RESIDENCE, RECORDS SHOW NO PERMITS EVER DRAWN. NOTIFIED MR. ESTRELLA OF THIS SITUATION HE STATED HE HAD REWIRED THE HOUSE HIMSELF AND DID NOT KNOW HE WAS REQUIRED TO OBTAIN A PERMIT AND INSPECTION. SINCE THE WIRING WAS NOT INSPECTED I NOTIFIED HIM THERE COULD BE NO CLEARANCE IF ALL OTHER ITEM CORRECTED |