Permit: T00EL02571

Parcel: 120074140


Addresses:

308 W AVIATION DR


Inspection Status: Denied

Inspection History: ELECTRIC - SERVICE UPGRADE

Permit Number - T00EL02571

Inspection Description - ELECTRIC - SERVICE UPGRADE

Inspection Status - Denied

Date Description Inspector Results Comments
04/05/2001 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0999* 1) USE CORRECT BREAKERS AMPACITY FOR CONDUCTORS INSTALLED 2) VERIFY LICENCED ELECTRICAL CONTRACTOR 3) LABEL BREAKERS 4) USE CORRECT HUB LISTED BY MANUFACTURER 5) A REFEE HAS BEEN ISSUED
03/01/2001 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0245* 1) COULD NOT VERIFY GAS PIPE BOND. 2) FITTINGS FOR CONDUIT TO HOUSE NEED TO BE RAIN TITE. 3) BREAKERS IN PANEL NEED TO BE SAME BRAND MAKE AS MANUFACTURER OF PANEL. 4) INSTALL BOND BUSHING ON 1" CONNECTOR 5) TEMP WIRE TO NEW SERVICE IS A SAFTEY ISSUE. HIRE OR GET A LICENCED CONTRACTOR TO DO JOB CORRECTLY OR POWER WILL BE DISCONNECTED PERMANENTLY. 6) 5 DAYS TO COMPLY
11/14/2000 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0999*
WILL NEED A LICENSED C-11 CONTRACTOR TO DO WORK ALL TO STRICLTY COMPLY WITH CODE
IMPROPER WIRING METHOD
USING NON RAINT EQUIPMENT
NEEL PLAN
11/02/2000 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0999*
NEED PERMANENT ADDRESS TAG METAL OR UNGROUND
NEED GAS WATER BOND
PARTIAL BOND AS BACKER TO MOUNT SERVICE IS NOT SUITABLE FOR THE ENVIROMENT