Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/06/2001 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection 0000* DISPOSAL WILL NOT BE USED. OWNER WISHES TO ELIMINATE CIRCUIT | |
| 04/03/2001 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000* 1) NEED K.O. SEAL AND USE ROMEX CONNECTOR AT KITCHEN LIGHT 2) 2 SEPERATE CIRCUITS FOR KITCHEN COUNTER RECEPTICLE REQUIRED ON GFI AND NEED DISPOSAL SWITCH 3) NEED ROMEX FOR BATH EXHAUST | |
| 03/30/2001 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0999* LOCKED AT SITE | |
| 03/07/2001 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0999* 1) NEED APPROVED PLAN 2) USE ROMEX CONNECTOR TO HOLD WIRE IN BOXES - NOT KNOCK OUT BUSHINGS 3) COMPLETE ALL MAKE UP 4) CONNOT HAVE ROMEX CABLE PROTRUDE INTO BOX OVER 1/2". A REFEE IS DUE BEFORE NEXT INSP. | |
| 01/24/2001 | ELECTRIC - INTERMEDIATE | Denied | FINISH MAKE UP OF ALL BOXES HAVE APPROVED PLANS AT SITE AND WIRE ACCORDING TO PLANS |
|
| 01/08/2001 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0245* SUPPORT BOXES IN WALLS MC CABLE NEED TO BE SUPPORTED AND AT LEAST 1 1/4" BACK IN WALL FROM SURFACE SUPPORT ROMEX AND MC IN CEILING |