Permit: T00EL01820

Parcel: 13811089A


Addresses:

6347 S FONTANA AV


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T00EL01820

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/19/2000 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
07/31/2000 ELECTRIC - FINAL Denied IVRS - Inspection 0999*
1. ADDRESS SERVICE DO THE SAME FOR ADJACENT EXIST SERVICE
2. TAG ALL UNIT NUMBERS DO THE SAME FOR ADJACENT EXISTING
3. IMPROPER CLEARANCE IN FRONT OF SERVICE
4. REMOVE L.B. AND ELBOW FROM BOTTOM OF SERVICE PLUG HOLE
5. EXPOSE RODS GAS BOND MAKE GROUNDING ELECTRODE SYSTEM COMMON TO BOTH SERVICES
6. NEED AN ELECTRICAL PLOT PLAN AND INDICATE THE EXTENT OF NEW WORK