Permit: T00EL00397

Parcel: 11618250B


Addresses:

1004 W CONGRESS ST

Inspection Status: Correction Required

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
02/16/2000 ELECTRIC - RECONNECT Correction Required ADDTL COMMS - 1. INSTALL LIGHT FIXTURE IN HALL (MISSING) 2. PANEL IS REQUIRED TO HAVE CLEARANCE IN FRONT OF IT 30 WIDE, 36 OUT IN FRONT-SHELVES IN FRINGE ON THIS CLEARANCE THEY WILL HAVE TO BE MOVED. 3. NEUTRALS AND GROUNDS ARE NOT SUPPOSED TO BE TIED TOGETHER 4. INSTALL PANEL COVER 5. ROMEX HAS TO BE PHYSICALLY PROTECTED AND DEVICES COVERED 6. FEED FROM SERVICE DOES NOT FEED PANEL IN SPACE CANNOT LOCATE J-BOX. OBTAIN A GENERAL REPAIR PERMIT FOR MOVING WALLS IF YOU ARE DOIN SO.
02/16/2000 ELECTRIC - RECONNECT Denied DENIED