Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 08/07/2006 |
PLUMBING - SEWER HCS CONNECT |
|
Approved |
|
| 01/17/2002 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000*1.) 4" HCS CONNECTION 116' EAST OF MHSA 2 4 HCS CONNECTION 156' EAST OF MHSA. |
| 01/15/2002 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000*TEST MH TO MH8A & MH8A TO CLEANOUT EAST OK FM 1/15/2002 |
| 01/08/2002 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000*3 SEWER SECTIONS APPROVED MH3A-4A MH 6A TO 12A MH 12A TO MH 9A. |
| 12/18/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000*1.) THIS INSPECTION IS FOR SITE SEWER FOR M.H. TO 15 @ L.4 AND HCS CONNECTION FOR L-4 @12 2.) SOIL WATER TEST IS OK 5.) OK FOR BACKFILL. |
| 12/14/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Not ready for Inspection |
|
| 12/12/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000*1.) AIR PRESSURE TEST ON SITE SEWER FOR 12" MAIN FROM M.H. 5-1 TO 3-A AND MH#5-A TO 6-A ARE OK. |
| 10/25/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000*SEWER FROM M.H. 8-A EAST 78' OK TO COVER. |
| 10/15/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000*SEWER TESTED OK FROM MH IA TO MA2A MH2A TO MH3A. MH 2A TO MH 2A. |
| 10/11/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 10/10/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Not ready for Inspection |
IVRS - Inspection 0000*1.) NOT READY FOR INSPECTION. |
| 10/03/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 09/28/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000*1) 6" C.I. WASTE SYSTEM FAN COOLING TO |
| 09/25/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 09/24/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000*8" SEWER SOUTH FROM MH8A 1501 |
| 09/20/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000*8" SOUTH TO MH. |
| 09/13/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000*8" SEWER FROM 1 + 40 1 + 75 OK TO COVER. |
| 09/12/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000*8" FROM 1750 TO 1850 12" MH 3 A 0+00-050. |
| 09/07/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000*8" PVC MH 4A TO 3A 8" PVC FROM MH 4A SOUTH 1/2 DISTANCE TO MHS A. |
| 09/04/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 06/05/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 06/01/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 05/30/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 05/29/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 05/25/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000*489' OF SITE SEWER INSTALLED THIS DATE.SIR TEST SEWER ST LATER DATE. |
| 05/24/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000*150' 12" OK TO COVER AIR TEST LATER. |