Permit: T00CM05109

Parcel: 128100570


Addresses:

5441 E WILLIAMS BL


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T00CM05109

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/11/2001 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) ALL CORRECTION MADE OK 2.) OFFENDING TOILET PAPER DISPENSER REMOVED CLEARANCE OK 3.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS.
08/28/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) CONCERNING THE LAST NOTE ON 7/26/01 I WILL ACCEPT THE CLEAN OUT UNDER THE LAVATORIES IN LIEN AT CLEAN OUT BEHIND WATER HEATER. 2.) BATH BATHROOMS I CHECKED HAD CLEARANCE PROBLEMS 13 1/2" OR 14" FROM CENTER LINE TO OSBTRUCTION IS NOT ACCEPTABLE.
07/26/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) REQD MINIMUM 15" FROM SIDEWALL OR OBSTRUCTION TO CENTERLINE OF WATER CLOSET-3 PLACES 2.) INSTALL UNION ON DOWNSTAIRS T & P DRAIN LINE 3.) MOVE UPSTAIRS WATER HEATER, OR ROUTE 2" CLEAN OUT TO ALLOW 12" CLEARANCE IN FRONT.
07/25/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) PROVIDE CERTIFICATION FOR REDUCED PRESSURE BACKFLOW PREVENTER 2.) HAVE PLUMBER COMPLETE PUNCH LIST, AND MAKE SURE EVERYTHING IS READY, BEFORE CALLING IN A FINAL INSPECTION. ESPECIALLY CHECK CLEARANCE IE. 15" FROM SIDEWALL OR OBSTRUCTION TO CENTER OF W.C. AND 2" CLEAN OUT REQUIRE 12" CLEARANCE IN FRONT OF THE CLEAN OUT.