Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T00CM05109
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/11/2001 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*1.) ALL CORRECTION MADE OK 2.) OFFENDING TOILET PAPER DISPENSER REMOVED CLEARANCE OK 3.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS. | |
08/28/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) CONCERNING THE LAST NOTE ON 7/26/01 I WILL ACCEPT THE CLEAN OUT UNDER THE LAVATORIES IN LIEN AT CLEAN OUT BEHIND WATER HEATER. 2.) BATH BATHROOMS I CHECKED HAD CLEARANCE PROBLEMS 13 1/2" OR 14" FROM CENTER LINE TO OSBTRUCTION IS NOT ACCEPTABLE. | |
07/26/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) REQD MINIMUM 15" FROM SIDEWALL OR OBSTRUCTION TO CENTERLINE OF WATER CLOSET-3 PLACES 2.) INSTALL UNION ON DOWNSTAIRS T & P DRAIN LINE 3.) MOVE UPSTAIRS WATER HEATER, OR ROUTE 2" CLEAN OUT TO ALLOW 12" CLEARANCE IN FRONT. | |
07/25/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) PROVIDE CERTIFICATION FOR REDUCED PRESSURE BACKFLOW PREVENTER 2.) HAVE PLUMBER COMPLETE PUNCH LIST, AND MAKE SURE EVERYTHING IS READY, BEFORE CALLING IN A FINAL INSPECTION. ESPECIALLY CHECK CLEARANCE IE. 15" FROM SIDEWALL OR OBSTRUCTION TO CENTER OF W.C. AND 2" CLEAN OUT REQUIRE 12" CLEARANCE IN FRONT OF THE CLEAN OUT. |