Permit: T00CM05106

Parcel: 128100570


Addresses:

5451 E WILLIAMS BL


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T00CM05106

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
04/24/2001 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000* PERMANENTLY AFFIX METAL TAG TO REGULATOR ON ROOF
03/30/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*
03/02/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000* 1) BATHROOMS STUBBED UP THROUGH THE FLOOR 2) MOP SINK AND BREAKROOM SINK RISERS ONLY 3) DWV ABS UNDERGROUND OK
WATER TEST OK 4) OK TO COVER 5) SHOWERS AND FLOOR DRAINS INSTALLED FOR T.I. TO BE APPROVED LATER-OK TO COVER 6) PARTIAL WATER RISER OK FOR BLDG 4 ABR SIL-FOS'D JOINT UNDER SLAB OK BLDG 5 NCS 100# TEST OK 7) BLDG SEWER 6" SDR-35 OK TO SIDEWALK 10' WATER TEST OK OK TO COVER WILL INSP. FINAL CONNECTION AT STREET CUT