Permit: T00CM04468

Parcel: 128010010

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
02/08/2002 ELECTRIC - INTERMEDIATE Approved
07/25/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*
07/11/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.)MAIN LOBBY CIELING & WALL LIFING.
07/05/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.PREP. RM WORTH 2. 2.) AUX CONNCESSION AREA SOUTH. 3.) SOUTH STORE ROOM CLNG.
07/02/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.AUX CONCESSION #3 PART R.I. 2.) SO. HALL ABVCLNG. OK
06/28/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*MAIN PREP ROOM, OK
06/27/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*RM C-257 CEILING 2036 OK 257 252 253 254 CEILING 2036 OK FINISH SERVICE TIES RM B-204 PNL WALLS 2035 OK TO COVER
06/21/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*WALLS IN 2ND FLOOR LOBBY WEST + SOUTH OK
06/20/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*
06/14/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*LOBBY NORTH AND EAST WALL.1)PROJECTIONS AREAS B AND C.2)PROMENADE AREA A-NORTH.3)BATHROOM (MENS) PROMENADE SOUTH.
06/08/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1)POWER TRANSFORMER AND FEEDERS INTO MAIN PANEL LANDING LUGS.
06/07/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*3RD FLOOR GEAR.
05/30/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*BOX OFFICE LOBBY.PREP ROOM #3 AND CONSESSION STAND.PREP ROOM #2 AND CONSESSION STAND.
05/26/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1)WALL ROUGH-IN,EMT AND BOXES BREAK RM, AND CHANGE RM.2)STORAGE.3)WASTE ROOM.
05/17/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*PARTIAL,1)MENU BATH NORTHSIDE-ABOVE.2)JANITORS CLOSET.
05/09/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000* WALL ROUGH IN OF ELEVATOR LOBBY PROJECTION LEVEL
05/02/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000* 1) PROJECTION LEVER MAIN ELEC. DIST. CENTERS 2) BATHROOMS AND ARCADE 2ND FLOOR
04/25/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000* 1) LOBBY CEILING LIGHTING
2) TH. 4 EXIT LIGHTING 3) VOMITORY HALL ROUGH IN #13,#14 4) #15 EXIT HALL 5) STORAGE NEXT TO 15
04/19/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*PARTIAL, ROUGH OK TO COVER WALLS BOX OFFICE & BOX OFFICE LOBBY. SIDE WALLS THEATERS, 12,13,14, 15,16, & 17. PNL PLA& PLAA-, MENS ROOM # 1- EQUIPMENT ROOM W/PNL'S PK1,PK2,P3B, LCPP3B ALL OK TO COVER.
04/17/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*OK WALLS RM # MANAGEMENT OFFICE, SAFE ROOM.
04/11/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000* TICKET BOOTH LOBBY LIGHTING
03/29/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000* AISLE AND PERIMETER LO-VO LITING AND CONVENIENCE OUTLET. THEATERS #3-11
03/09/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000* SOUTH END OF CORRIDOR OK
02/14/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000* SECURED STORAGE AREA
02/06/2001 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*
PARTIAL 13-20
01/12/2001 ELECTRIC - INTERMEDIATE Partial Approval INTERMEDIATE 1-12 THEATERS, PROJECTION LEVEL PROMENADE LEVEL, CORRIDORS NORTH SIDE (SIDE A) OK TO COVER WALLS ON ALL ABOVE