Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - PROGRESS
Permit Number - T00CM03704
Inspection Description - PLUMBING - PROGRESS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/23/2001 | PLUMBING - PROGRESS | Approved | ||
06/26/2001 | PLUMBING - PROGRESS | Partial Approval | 1.) SHOWER VENT,REPAIRED VENT, TEP DRAIN OK 2.) OK TO SHEETROCK ALL AREAS | |
06/13/2001 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000*1. MEN'S & WOMEN'S BATHROOMS, 1. ABS DWV OK TO ABOVE CEILING WATER TEST 1O' HEAD. 2. COPPER IN BATHROOMS OK, PRESSURE TEST OK, 3, OK TO SHEETROCK BATHROOMS 4. NEED TO SEE: SHOWER VENT, REPAIRED VENT, PT R FOR BATHROOM | |
05/28/2001 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000*1)TIE-IN TO INTERCEPTOR OK.2)INTERCEPTOR TO BACKWATER VALUE OK.3)BACKWATER VALUE TO SEWER TIE IN OK.4)WATER TEST ON SEWER, INTERCEPTOR, TO BACKWATER VALUE OK.5)NEED TO SEE VENT INTERCEPTOR, AFTER BACKFILLED.5)OK TO BACKFILL INTERCEPTOR. | |
03/27/2001 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000* 1) 3" HORIZONTAL VENT BELOW FLOOD RIM OK 2) WILL RED LINE ON AS BUILTS. NOTE: BY INCREASING HORIZONTAL VENT ONE PIPE SIZE WE WERE ABLE TO EXTEND IT TO NEAREST PARTITION | |
03/19/2001 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000* 1) 4" DRAIN IN MIDDLE OF HANGER HAS A 2" VENT SEE TABLE 7-5 ONLY 1/3 OF DEVELOPED LENGTH OF VENT MAY BE RUN IN A HORIZONTAL POSITION 2) BE SURE AND RED LINE THE CHANGE TO PLAN |