Permit: T00CM03512

Parcel: 137335720


Addresses:

1840 W VALENCIA RD

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
04/24/2001 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*
04/23/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999* 1) FURNCO NOT ACCEPTABLE FOR ROOF DRAIN CONNECTIONS 2) PIPE MUST BE SUPPORTED BY HANGERS NOT THE COUPLING
3) STRAP VERTICAL COPPER
04/09/2001 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000* 1) NO CONNECTION MAY BE MADE BETWEEN METER AND RPBP 2) TEST TO 50# AND CALL BACK
04/05/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000* 1) 2 WAY C.O. FITTING AT BLDG DRAIN AND BLDG SEWER OK 2) OK TO COVER