Inspection Status: Denied
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/06/2000 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0950*/ 1. PROVIDE PROOF OF ELECT SUB PANEL GROUND. EXPOSE RODS. 2. INADEQUATE SEWER VENT--MUST HAVE EQUIVALENT OF 8" SEWER LINE IN VENT SYSTEM. 3. EXPOSE SEWER LINE FROM GARAGE TO SEWER CONNECTION. 4. INSTALL SEWER CLEAN OUT. (2 WAY). 5. GFCI ELECTRIC OUTLET REQUIRED ON 12" COUNTER RT OF RANGE. 6. INADEQUATE EGRESS FROM BEDROOM--WINDOW MUST COMPLY WITH UBC SECTION 310.4. 7. INADEQUATE CEILING HEIGHT IN LIVING ROOM. 7'-6" REQUIRED ACTUAL 7'-4". 8. EXPOSE RANGE OUTLET. 9. EXPOSE ELECTRIC UNDERGROUND CONDUIT. |