Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T00CM02654

Parcel: 122130700


Addresses:

3927 E MABEL ST

Inspection Status: Denied

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
10/06/2000 BUILDING - FINAL Denied IVRS - Inspection 0950*/ 1. PROVIDE PROOF OF ELECT SUB PANEL GROUND. EXPOSE RODS. 2. INADEQUATE SEWER VENT--MUST HAVE EQUIVALENT OF 8" SEWER LINE IN VENT SYSTEM. 3. EXPOSE SEWER LINE FROM GARAGE TO SEWER CONNECTION. 4. INSTALL SEWER CLEAN OUT. (2 WAY). 5. GFCI ELECTRIC OUTLET REQUIRED ON 12" COUNTER RT OF RANGE. 6. INADEQUATE EGRESS FROM BEDROOM--WINDOW MUST COMPLY WITH UBC SECTION 310.4. 7. INADEQUATE CEILING HEIGHT IN LIVING ROOM. 7'-6" REQUIRED ACTUAL 7'-4". 8. EXPOSE RANGE OUTLET. 9. EXPOSE ELECTRIC UNDERGROUND CONDUIT.