Permit: T00CM02109

Parcel: 12407190A


Addresses:

860 E BROADWAY BL

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
01/23/2001 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*
GAS PRESSURE TEST OK 15#
GS PIPING OK
VALVES AND CONNECTIONS OK
01/22/2001 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*
STILL NEED HORIZONTAL SUPPORT AT ROOF DRAINS
RPBP TURNED BACK TO TRUE OK
COPPER PIPE AT WAER HEATER TOUCHING
RUN PAN DRAIN AND T&P SEPARATE AND FULL SIZE TO JANITORS SINK
ONLY ONE SLIP NOT ALLOWED ON OUTLET OF P-TRAP
SUPPORT CONDENSATE DRAIN AT JANITORS SINK
URINAL AT WRONG ELEVATION
LAVATORIES AT INCORRECT HEIGHT
18" MINUMUM FROM SIDEWALL TO CENTER OF H.C. WATER CLOSET
NEED TO SEE 10# AIR TEST ON GAS LINES
WILL NOT APPROVE BLOCKING ON GAS LINES
WILL NOT APPROVE BLOCKING ON GAS PIPE
ADD 2 HOLE STRAPS WHERE NEEDED
CHANGE OVERSIZED 2 HOLE STRAPS TO CORRECT SIZE (SEE DETAIL M-2)
CONDENSATE DRAINS NOT TO PLAN
THIS MAY NOT INCLUDE ALL CODE VIOLATIONS PLEASE CHECK YOUR ENTIRE JOB BEFORE CALLING BACK IN