Permit: T00CM00919

Parcel: 125122040


Addresses:

3322 E 3RD ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
10/18/2018 BUILDING - FINAL Approved
10/05/2000 BUILDING - FINAL Denied IVRS - Inspection 0999*1. ALL COUNTER ELECTRIC OUTLETS IN KITCHEN MUST BE GFCI PROTECTED SOUTH AND EAST WALLS DO NOT COMPLY. 2. ELECTRIC OUTLET (GFCI) REQUIRED ON ALLCOUNTER TOPS IN EXCESS OF 12" WIDE IN KITCHEN. 3. ELECT OUTLET LOOSE AT WEST END OF SOUTH KITCHEN WALL. 4. WINDOW WITHIN 24" OF FAMILY ROOM DOOR MUST BE SAFETY GLAZED. ALSO BEDROOM 3 AND 4 WINDOWS. 5. BEDROOM SMOKE DETECTORS CANNOT BE WITHIN 36" OF AIR REGISTERS. 6. YOU MUST PROVIDE LADDER ACCESS TO ATTIC FURNACE.
09/15/2000 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*/CITY ORDINANCE REQUIRES THE HOUSE ADDRESS BE POSTED ON THE HOUSE AT A PLACE VISIBLE FROM THE STREET. MINIMUM SIZE NUMBERS OF 3" HIGH. RECALL INSPECTIONS AND ARRANGE TO BE HOME.