Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/10/2002 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*PLBG. FINAL IS OK 2.) ALL REVISIONS OF WASTE & VENT SYSTEM HAVE BEEN MADE & APPROVED. 3.) OK FOR C OF O. |
| 08/02/2002 |
PLUMBING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*1.) PLBG FINAL A SOUTH WING 1ST & 2ND FLOORS IS OK 2.) NOTE: MUST PROVIDE REVISED & APPROVED DRAWINGS ON ALL REVISIONS ON WASTE & VENT SYSTEM AND SITE SEWER. |
| 07/16/2002 |
PLUMBING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*1.) KITCHEN IN BLDG C FINAL IS OK 2.) OK FOR TEMP C OF O. |
| 07/10/2002 |
PLUMBING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*1.) OK FOR TEMP C OF O. 2.) FOR BLDG C ONLY. 1.) TRIPLE COMT SINKS REQUIRES C.O. @ UPSTREAM END OF CONTINUOUS WASTE 3.) GAS SHUT OFF VALVES MUST BE MAX 3'-0" FROM REGULATOR. 4.) MEN RESTROOM URINAL FLUSH VALVE DISCHARGE TUBE MUST HAVE MIN 6" FROM C L LEVEL TO TOP OF FIXTURE. 5.) LINT CATCHER @ LAUNDRY RM REQUIRES A BACKFLOW PREVENTER #007. 6.) REMOVE OLD 3" PVC FROM A.W. DRAINS AND REPLACE WITH NEW PIPE (GREEN GLUE WITHIN STRUCTURE. 7.) FLOW CONTROL VENT CONNECTION MUST BE BRASS. |
| 06/25/2002 |
PLUMBING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000* |
| 06/10/2002 |
PLUMBING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*1.) PLBG. FINAL IS OK FOR WING C NORTH ONLY. |
| 06/05/2002 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) PLBG FINAL FOR RMS C-110 C-109, C-111,C-116,C-119, C-125,C-126 IS OK 2.) COUNTER TOPS FOR MENS & WOMENS RESTROOMS DOES NOT MEET ADA REQUIREMENTS ON HEIGHTS FROM FINISH FLOOR. |
| 11/20/2001 |
PLUMBING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*1.) PLBG. TEMP C OF O. IS OK FOR BLDG. A ONLY. |
| 08/31/2001 |
PLUMBING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*1.) PLBG FINAL FOR BLDG. B 2ND FLOOR IS OK. |
| 08/30/2001 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) MUST REMOVE ALL PANELS @ LAVATOR BEFORE INSPECTION AS REQUESTED 2.) SEVERAL WATER CLOSETS AND SHOWER TRIM NOT INSTALLED 3.) CALL WHEN 100% COMPLETED. |
| 08/22/2001 |
PLUMBING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*1.) FIRST FLOOR BLDG. B FINAL IS OK. |