Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T00CM00852

Parcel: 12109290B


Addresses:

2221 N ROSEMONT BL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/10/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*PLBG. FINAL IS OK 2.) ALL REVISIONS OF WASTE & VENT SYSTEM HAVE BEEN MADE & APPROVED. 3.) OK FOR C OF O.
08/02/2002 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*1.) PLBG FINAL A SOUTH WING 1ST & 2ND FLOORS IS OK 2.) NOTE: MUST PROVIDE REVISED & APPROVED DRAWINGS ON ALL REVISIONS ON WASTE & VENT SYSTEM AND SITE SEWER.
07/16/2002 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*1.) KITCHEN IN BLDG C FINAL IS OK 2.) OK FOR TEMP C OF O.
07/10/2002 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*1.) OK FOR TEMP C OF O. 2.) FOR BLDG C ONLY. 1.) TRIPLE COMT SINKS REQUIRES C.O. @ UPSTREAM END OF CONTINUOUS WASTE 3.) GAS SHUT OFF VALVES MUST BE MAX 3'-0" FROM REGULATOR. 4.) MEN RESTROOM URINAL FLUSH VALVE DISCHARGE TUBE MUST HAVE MIN 6" FROM C L LEVEL TO TOP OF FIXTURE. 5.) LINT CATCHER @ LAUNDRY RM REQUIRES A BACKFLOW PREVENTER #007. 6.) REMOVE OLD 3" PVC FROM A.W. DRAINS AND REPLACE WITH NEW PIPE (GREEN GLUE WITHIN STRUCTURE. 7.) FLOW CONTROL VENT CONNECTION MUST BE BRASS.
06/25/2002 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*
06/10/2002 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*1.) PLBG. FINAL IS OK FOR WING C NORTH ONLY.
06/05/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) PLBG FINAL FOR RMS C-110 C-109, C-111,C-116,C-119, C-125,C-126 IS OK 2.) COUNTER TOPS FOR MENS & WOMENS RESTROOMS DOES NOT MEET ADA REQUIREMENTS ON HEIGHTS FROM FINISH FLOOR.
11/20/2001 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*1.) PLBG. TEMP C OF O. IS OK FOR BLDG. A ONLY.
08/31/2001 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*1.) PLBG FINAL FOR BLDG. B 2ND FLOOR IS OK.
08/30/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) MUST REMOVE ALL PANELS @ LAVATOR BEFORE INSPECTION AS REQUESTED 2.) SEVERAL WATER CLOSETS AND SHOWER TRIM NOT INSTALLED 3.) CALL WHEN 100% COMPLETED.
08/22/2001 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*1.) FIRST FLOOR BLDG. B FINAL IS OK.