Permit: T00CM00852

Parcel: 12109290B


Addresses:

2221 N ROSEMONT BL

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
03/07/2002 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) THIS INSPECTION IS FOR BLDG. A 3.) OK TO BACKFILL TRENCH.
03/05/2002 PLUMBING - ROUGH, SOIL Partial Approval 1.) SOIL WATER TEST IS OK 2.) THIS INSPECTION IS FOR ROUGH PLBG. FOR NORTH C BLDG. ONLY.
02/27/2002 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*1.) AIR PRESSURE TEST FOR SOIL IS OK 2.) THIS INSPECTION IS FOR GREASE LINE ONLY IN KITCHEN 3.) OK TO BACKFILL TRENCH.
02/21/2002 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) THIS INSPECTION IS FOR KITCHEN AREA BLDG. C ONLY. 3.) OK TO BACKFILL TRENCH.
02/19/2002 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*1.) AIR TEST 5LBS IS OK ALL OF ROUGH PLBG. IN BLDG C SOUTH EXCEPT THE KITCHEN.
02/15/2002 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*1.) AIR PRESSURE TEST OF 5LBS ON SOIL WASTE IS OK 2.) OK TO BACKFILL TRENCH. 3.) THIS INSPECTION IS FOR C BLDG. SOUTH LESS KITCHEN.
02/13/2002 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection 0000*NOT READY FOR INSPECTION.
12/11/2001 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection 0000*1.) HAD MEETING ON WORK TO BE DONE FOR TEMP LAUNDRY RM.
09/23/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*UNDERGROUND 1.) SOUTH EXTENSION BLDG. "A" 6" ABS BLDG DRAIN TO EXISTING OUTSIDE BLDG OK WATER TEST 4 RISERS 3, CLEAN OUTS. OK TO TIE-IN INSIDE AND OUTSIDE BLDG"A" OK FOR BACKFILL PAID BY CHECK #8853.
05/03/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*
04/19/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000* 1) SOIL WATER TEST OK
2) THIS INSP. WAS FOR MECH ROOM ONLY 3) OK TO BACKFILL
04/18/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000* THIS INSPECTION IS FOR #AL NORTH TO A1 COLUMS ONLY OK TO BACKFILL TRENCH
04/12/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000* 1) SOIL WATER TEST OK
2) THIS INSP. IS FOR ALL U.G. SOIL FROM NORTH END OF BLDG A TO COLUMN #AF 3) OK TO BACKFILL
04/03/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000* 1) FINAL CONNECTION FOR RAIN LEADERS AT SOUTH COURTYARD OK 2) OK TO BACKFILL TRENCH
03/05/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000* 1) SOIL WATER TEST OK 2) THIS INSP. IS FOR TRUNK LINE ONLY FROM COLUMN #AL TO COLUMN #AA 3) OK TO BACKFILL TRENCH
03/01/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000* 1) P.O.C OF RAIN LEADERS TO 6" SDR-45 OK 2) OK TO BACHFILL TRENCH 3) NOTE: THIS INSP WAS FOR NORTH COURT YARD OF BLDG B ONLY 4) APPROVED DRAINING SHOWS OVER FLOW RAIN HEADERS TO CONNECT TO 6" AND 12" STORM DRAINS.
02/26/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000* OK TO BACKFILL THIS INSP IS FOR COLUMN BL TO BK
02/23/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*SOIL WATER TEST OK FROM COLUMN BN TO BL
02/21/2001 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection 0000*
02/05/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*
SOIL WATER TEST OK
C.W. AIR TEST STUBBED UP INTO BLDG OK
OK TO BACKFILL TRENCH
THIS INSPECTION IS FOR ROUGH SOIL FROM COLUMN BK TO BF ONLY
01/25/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*
01/16/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*
1. PRE SLAB INSPECTION FOR PLUMBING OK
01/11/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*
SOIL WATER TEST OK
THIS INSPECTION IS FOR COLUMN #BF TO BC AND CENTER WING FROM COLUMN #3 TO 10
OK TO BACKFILL TRENCH
01/10/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*
01/08/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*
SOIL WATER TEST OK
THIS INSPECTION IS FOR ROUGH PLDG IN COLUMN #BC TO NORTH AND FROM 0 TO 3
OK TO BACKFILL TRENCH
01/05/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*
SOIL WATER TEST OK
THIS INSPECTION IS FOR NORTH WING FROM COLUMN #3 THRU #8 ONLY
OK TO BACKFILL TRENCH
01/04/2001 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection 0000*
HAD MEETING WITH CONTRACTOR ON SITE SEWER ONLY
12/20/2000 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*
SOIL WATER TEST OK
THIS INSPECTION IS FOR SOUTH WING OF BLDG B MAIN TRUNK LINE ONLY
OK TO BACKFILL TRENCH
12/11/2000 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*
SOIL WATER TEST OK
OK TO BACKFILL TRENCH
THIS INSPECTION IS FOR UNDERGROUND SOIL TRUNK LINE UP TO COLUMN BK TO NORTH
12/05/2000 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*
SOIL WATER TEST OK
THIS INSPECTION WAS FOR UNDERGROUND TRUNK LINE ONLY NO BRANCHES FOR COLUMN LINE BF TO NORTH ONLY
OK TO BACKFILL TRENCH