Permit: T00BU03639

Parcel: 116120870


Addresses:

621 N GRANDE AV

Inspection Status: Denied

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
12/04/2001 BUILDING - FINAL Denied 1.) NEED CLIPS @ N BEAM. 2.) NEED BLOCK BETWEEN RAFTOR @ N BEAM.
06/04/2001 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000$
05/16/2001 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000$ 1) NEED TO COMPLETE INSTALLATION OF TICO NAILS IN ALL HARDWARE
2) INSTALL A2.35 CLIPS ON RAFTERS TO BEAM
3) NEED 3-2X8 AT BEAM ONLY 2 INSTALLED
4) INSTALL A2.35 CLIP AT PORCH BEAM 5) INSTALL BOLTS IN BEAM SEATS PER DETAIL 6/6.1
6) OBTAIN AN ELECTRICAL PERMIT FOR WORK DONE