Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan: S02-034

Parcel: 138220770

Inspection Status: Passed

Inspection History: TRSP - PIA - Engineering Final - Completion of PIA Work (Final Lot Release/Acceptance)

Date Description Inspector Results Comments
07/24/2008 TRSP - PIA - Engineering Final - Completion of PIA Work (Final Lot Release/Acceptance) DLEE Approved Entered by SMONTIE1 - PLAN NO: I-2004-015
04/17/2008 TRSP - PIA - Engineering Final - Completion of PIA Work (Final Lot Release/Acceptance) DLEE Denied Entered by SMONTIE1 - PLAN NO. : I-2004-015 This office inspected the subject project on April 17, 2008, and found the following items in need of attention. Please consider this letter the punch list of items to be addressed/ rectified prior to the acceptance of improvements in the public rights-of-way by the City of Tucson for maintenance and operation. Future inspections will require a Letter of Certification that the Engineer of Record has resolved all punch list items. In addition to the following items, traffic Engineering may have additional punch list items pertaining to trafffic signage and striping. 1. The expansion material installed at Lot 17, at back of curb, is not city standards; it is not black asphaltic. 2.Expansion, material is missing from top of the curb access ramp on the SEC at Santa Clara Ave. and Carolchristine Pl. 3. At the intersection of Santa Clara and Carolchristine Pl. there are two patches, one for sewer and one for water that were replaced. These both have pulled away from the joints leaving unacceptable gaps. 4. The scupper cells do not measure 2' per plan but rather 20". Please provide data showing built cells will provide adequate room for the volume of flow. "As Built" plans to be submitted to show compliance with this item. 5. Curb access ramp on the north side of Carolchristine Pl. at Santa Clara is not built to plan. The "As Built" changes you referred to is not reflected on the black lines and "As Built" plans were not submitted to this office with your response letter. 6. Numerous cracks in the pavement were noticed. Please provide the Materials report for the asphalt. 7. The paint on the scupper steel plates located between lots 16 and 17 has worn down and rust is now present. Repaint. After completion of the punch list items, please insure that this office has received the items on the following list before requesting re-inspection. 1. As-Built Mylar : Original approved plan sheets with as-built notations with certifying engineer's initials and the Engineer of Record's seal and signature on the cover sheet.
09/12/2006 TRSP - PIA - Engineering Final - Completion of PIA Work (Final Lot Release/Acceptance) TSTOCKET Approved Entered by THAUSER1 - I-2004-015