Permit: DP22-0172

Parcel: 11451206B

Inspection Status: Partial Pass

Inspection History: ENGR Paving

Date Description Inspector Results Comments
07/15/2026 ENGR Paving Partial Pass Concrete PAAL, section north of round-a-bout: subgrade and reinforcement are good. Okay to pour this section.
07/21/2026 ENGR Paving Partial Pass Reinforced concrete cul-de-sac at main entrance: north section of is poured. West section base and reinforcement are good, okay to pour. East section base and reinforcement are good, okay to pour. South section base and reinforcement are good, okay to pour.
07/23/2026 ENGR Paving Partial Pass Sub-grade for the east half of the north road: PAAL and parking stalls’ depth, slopes, and compaction are good. Okay to lay AB.
07/28/2026 ENGR Paving Partial Pass Sub-grade at North entrance from Bear Canyon: Depths and compaction are good. Okay for AB.
07/29/2026 ENGR Paving Partial Pass AB on East side and East half of Northside, some areas need adjustment on North drive. Revisit tomorrow morning prior to pave.
07/30/2026 ENGR Paving Partial Pass East PAAL and parking is good to pave.
Northern entrance driveway from Bear Canyon is good to pave pending Right-of-Way's inspection.
North-East PAAL on the curve has been adjusted down, is good to pave pending tack coat.
North PAAL between East refuse enclosure and middle intersection is good to pave pending tack coat application.